swee ревизий этого фрагмента . К ревизии
1 file changed, 103 insertions
gistfile1.txt(файл создан)
@@ -0,0 +1,103 @@ | |||
1 | + | $ sudo smartctl -a /dev/sdb | |
2 | + | smartctl 7.5 2025-04-30 r5714 [x86_64-linux-6.15.6-0-stable] (local build) | |
3 | + | Copyright (C) 2002-25, Bruce Allen, Christian Franke, www.smartmontools.org | |
4 | + | ||
5 | + | === START OF INFORMATION SECTION === | |
6 | + | Model Family: Seagate BarraCuda 3.5 (CMR) | |
7 | + | Device Model: ST1000DM010-2EP102 | |
8 | + | Serial Number: /// | |
9 | + | LU WWN Device Id: /// | |
10 | + | Firmware Version: CC43 | |
11 | + | User Capacity: 1,000,204,886,016 bytes [1.00 TB] | |
12 | + | Sector Sizes: 512 bytes logical, 4096 bytes physical | |
13 | + | Rotation Rate: 7200 rpm | |
14 | + | Form Factor: 3.5 inches | |
15 | + | Device is: In smartctl database 7.5/5706 | |
16 | + | ATA Version is: ATA8-ACS T13/1699-D revision 4 | |
17 | + | SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s) | |
18 | + | Local Time is: Thu Jul 17 22:54:39 2025 PDT | |
19 | + | SMART support is: Available - device has SMART capability. | |
20 | + | SMART support is: Enabled | |
21 | + | ||
22 | + | === START OF READ SMART DATA SECTION === | |
23 | + | SMART overall-health self-assessment test result: PASSED | |
24 | + | ||
25 | + | General SMART Values: | |
26 | + | Offline data collection status: (0x00) Offline data collection activity | |
27 | + | was never started. | |
28 | + | Auto Offline Data Collection: Disabled. | |
29 | + | Self-test execution status: ( 0) The previous self-test routine completed | |
30 | + | without error or no self-test has ever | |
31 | + | been run. | |
32 | + | Total time to complete Offline | |
33 | + | data collection: ( 0) seconds. | |
34 | + | Offline data collection | |
35 | + | capabilities: (0x73) SMART execute Offline immediate. | |
36 | + | Auto Offline data collection on/off support. | |
37 | + | Suspend Offline collection upon new | |
38 | + | command. | |
39 | + | No Offline surface scan supported. | |
40 | + | Self-test supported. | |
41 | + | Conveyance Self-test supported. | |
42 | + | Selective Self-test supported. | |
43 | + | SMART capabilities: (0x0003) Saves SMART data before entering | |
44 | + | power-saving mode. | |
45 | + | Supports SMART auto save timer. | |
46 | + | Error logging capability: (0x01) Error logging supported. | |
47 | + | General Purpose Logging supported. | |
48 | + | Short self-test routine | |
49 | + | recommended polling time: ( 1) minutes. | |
50 | + | Extended self-test routine | |
51 | + | recommended polling time: ( 104) minutes. | |
52 | + | Conveyance self-test routine | |
53 | + | recommended polling time: ( 2) minutes. | |
54 | + | SCT capabilities: (0x1085) SCT Status supported. | |
55 | + | ||
56 | + | SMART Attributes Data Structure revision number: 10 | |
57 | + | Vendor Specific SMART Attributes with Thresholds: | |
58 | + | ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE | |
59 | + | 1 Raw_Read_Error_Rate 0x000f 081 063 006 Pre-fail Always - 167219986 | |
60 | + | 3 Spin_Up_Time 0x0003 097 097 000 Pre-fail Always - 0 | |
61 | + | 4 Start_Stop_Count 0x0032 082 082 020 Old_age Always - 19375 | |
62 | + | 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0 | |
63 | + | 7 Seek_Error_Rate 0x000f 080 060 045 Pre-fail Always - 114458610 | |
64 | + | 9 Power_On_Hours 0x0032 039 039 000 Old_age Always - 53809 | |
65 | + | 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0 | |
66 | + | 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 273 | |
67 | + | 183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 0 | |
68 | + | 184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0 | |
69 | + | 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 | |
70 | + | 188 Command_Timeout 0x0032 100 099 000 Old_age Always - 0 0 2 | |
71 | + | 189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0 | |
72 | + | 190 Airflow_Temperature_Cel 0x0022 062 051 040 Old_age Always - 38 (Min/Max 26/42) | |
73 | + | 193 Load_Cycle_Count 0x0032 088 088 000 Old_age Always - 25407 | |
74 | + | 194 Temperature_Celsius 0x0022 038 012 000 Old_age Always - 38 (0 12 0 0 0) | |
75 | + | 195 Hardware_ECC_Recovered 0x001a 001 001 000 Old_age Always - 167219986 | |
76 | + | 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 | |
77 | + | 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0 | |
78 | + | 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0 | |
79 | + | 240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 32831h+28m+46.301s | |
80 | + | 241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 32319385398 | |
81 | + | 242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 20789396862 | |
82 | + | ||
83 | + | SMART Error Log Version: 1 | |
84 | + | No Errors Logged | |
85 | + | ||
86 | + | SMART Self-test log structure revision number 1 | |
87 | + | Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error | |
88 | + | # 1 Short captive Completed without error 00% 53809 - | |
89 | + | # 2 Extended offline Aborted by host 90% 53778 - | |
90 | + | # 3 Short offline Completed without error 00% 0 - | |
91 | + | ||
92 | + | SMART Selective self-test log data structure revision number 1 | |
93 | + | SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS | |
94 | + | 1 0 0 Not_testing | |
95 | + | 2 0 0 Not_testing | |
96 | + | 3 0 0 Not_testing | |
97 | + | 4 0 0 Not_testing | |
98 | + | 5 0 0 Not_testing | |
99 | + | Selective self-test flags (0x0): | |
100 | + | After scanning selected spans, do NOT read-scan remainder of disk. | |
101 | + | If Selective self-test is pending on power-up, resume after 0 minute delay. | |
102 | + | ||
103 | + | The above only provides legacy SMART information - try 'smartctl -x' for more |
Новее